A-300 SC140 DSP Core Reference Manual
MOVES.4F
Instruction Formats and Opcodes
Notes: 1. ** indicates serial grouping encoding.
2. When the form (Rn + N0) is used in EA, the cycle count is increased by 1.
Instruction Fields
Da:Db:Dc:Dd k Data Register Quad
EA MMM Effective Address Notation
Rn RRR Address Register
R0
$0000 0050
L0:D0
$1:$0 08000 0000
L1:D1
$0:$00 7FFF FFFF
L2:D2
$1:$87 6543 2100
L3:D3
$0:$FF 8765 4321
$0050
$7FFF
$0052
$7FFF
$0054
$8000
$0056
$8765
Instruction Words Cycles Type Opcode
15 8 7 0
MOVES.4F 11
2
1 0*001k0011MMMRRR
Da:Db:Dc:Dd,(EA)
0 D0:D1:D2:D3 1 D4:D5:D6:D7
Note: This instruction can specify D8-D15 as operands by using a prefix.
000 (Rn+N0) 010 (Rn) 100 (Rn)+N0 110 (Rn)+N2
001 (Rn)– 011 (Rn)+ 101 (Rn)+N1 111 (Rn)+N3
000 R0 010 R2 100 R4 110 R6
001 R1 011 R3 101 R5 111 R7
Note: This instruction can specify R8-R15 as operands by using a high register prefix.
Register/Memory Address Before After